Conductivity |
|
|
|
|
|
 |
Conductivity
sensors, SC42/FF40/FS40/FD40 |
 |
 |
- Wide range of
sensors to suit most process conditions.
- High precision of
the cell constant (Field calibration not necessary).
- Sensors for
ultra-pure water applications.
- Built-in
resistance thermometers Pt 1000 or Ni 100 for
automatic temperature compensation.
- Optional material
certificate 3.1 B according to EN-10-24 (DIN50049) for
stainless steel sensors.
- Optional quality
inspection certificate.
|
 |
Conductivity sensors
SX42 |
 |
 |
- High
temperature and pressure ratings
- Built-in
temperature resistor: Pt 1000
- High
precision of the cell constant
- Fast
temperature response
- Plug and
cable form a water tight connection to IP65
- Model with
glange has an integral connection box
- Threaded
models have standardized connections 1"NPT or R1
|
 |
Sensors cables WU40
for conductivity sensors SC42/SX42 |
 |
 |
- The plug/socket
connection bezween cell and cable meets the
requirements of IP65.
- The cable is 6-wiremulticore
and covered with a thermoplastic PVC.
|
 |
Sensors
conductivity SC4A/PR4A |
 |
 |
- Precise
individually calibrated cellconstant.
- Fast temperature
response.
- Built-in Pt 1000Ώ
RTD temperature sensor.
- Fixed cable length
3, 5, 10, 15 or 20 meters.
- Direct process
insertion.
- Wide range of
mountings.
- Compatible with
PR4A retractably assembly.
- the senor is
polished to meet pharmaceutical requierements.
|
 |
Transmitter for
conductivity or resistivity SC202G/S |
 |
 |
- Universal
conductivity/resistivity, software switchable.
- On-line sensor
checking.
- HART communications
interface (DD available).
- Password protection
for all levels of software.
- Easy to use EXA
control panel.
- Matrix temperature
compensation for pure water applications.
|
 |
Transmitter for conductivity or
resistivity SC202G-F |
 |
 |
- Universal
conductivity/resistivity, software switchable.
- On-line sensor
checking.
- HART
communications interface (DD available).
- Password
protection for all levels of software.
- Easy to use EXA
control panel.
- Matrix
temperature compensation for pure water applications.
|
|
 |
Converter for
conductivity or resistivity SC450G |
 |
 |
-
IP66/NEMA4X 1/2DIN enclosure for Field mounting and
Panel mounting.
-
Interactive display with choice out of 5 languages:
English, French, German, Italian and Spanish.
-
Trending display for up to 2 weeks.
-
On-screen logbooks store calibration data, configuration
changes and events.
-
Advanced Process Temperature Compensation.
-
Cell fouling mounting
|
 |
Conductivity Meter
SC100 |
 |
 |
- 96 x 96 mm panel
mount design for indoor use
- Practical functions
packed in a compact housing
- Large 4-digit
display
- One analog output
and two/four contact outputs as standard feature
- Easy access to
routine maintenance mode
- Self-diagnostics (e.g.,
calibration failure, measuring range failure,
converter failure)
|
|
 |
Panel Mounted Converter for Conductivity or ResistivitySC150 |
 |
 |
- Compact panel mount
design
- Interactive touch
screen interface
- Specialized process
temperature compensations
- On-line sensor
checking
- HART communications
(DD available)
- Adjustable output
damping
- IP65 front panel
|
|
 |
Converter for Dual Cell Conductivity or
Resistivity DC402 |
 |
 |
- Differential, ratio
or calculated outputs
- Universal
conductivity/resistivity, software switchable
- Self-tunin
measuring signal
- Four fully
configurable SPDT contact outputs
- Two fully
configurable mA outputs
- UPS 23 monitoring
|
|
 |
Inductive Conductivity Sensor and Fittings ISC40 |
 |
 |
- Inductive
Conductivity technique for elimination of fouling and
polarizetion errors.
- Wide bore sensors
for long term stability.
- Installation
flexibillity by wide range of holders and by the use of
universal bulkhead construction.
- All applications
where the 6 decade rangebillity is necessary for
accurate process control.
|
|
 |
2-wire Transmitter Inductive
Conductivity Meter IC200G/S |
 |
 |
- Process optimised
temperature compensation to fit the instrument in any
application.
- Free programmable
setting of the output rande, includina a 21-step table
output to linearise the output function e.g. to % by
weight.
- Passive 2-wire
system, 4 to 20 mA for easy installation at low costs
and sage operation at 24 Volt DC.
- Intrinsically
safe version available in same design for hazardous
areas. ATEX, FM and CSA approved.
|
|
 |
2-wire Transmitter
for Conductivity/Resistivity ISC202G-S |
 |
 |
-
Process optimised temperature
compensation to fit the instrument in any application
-
Extremely wide measuring range
(> 6 decades) while maintaining a high resolution and accuracy
using only one sensor type : Minimum Conductivity 1.00 µS/cm
- Maximum Conductivity 2.00
S/cm.
- Free programmable setting of
the output range, including a 21-step table to linearise the
output function e.g. to weight%.
- Proven simple 3-level
operation system using YES/NO prompts where each level can
seperately be protected from unwanted access by a 3-digit
passcode.
|
|
|
2-wire Transmitter for Conductivity/Resistivity ISC202G-F
|
 |
 |
-
Process
optimised temperature compensation to fit the
instrument in any application
-
Extremely
wide measuring range (> 6 decades) while maintaining a
high resolution and accuracy using only one sensor
type : Minimum Conductivity 1.00 µS/cm
- Maximum Conductivity
2.00 S/cm.
- Free
programmable setting of the output range, including a
21-step table to linearise the output function e.g. to
weight%.
- Proven
simple 3-level operation system using YES/NO prompts
where each level can seperately be protected from
unwanted access by a 3-digit passcode.
|
 |
Conductivity Meter
ISC450G |
 |
 |
- Predefined OIML
standard solutions.
- Predefined matrices
for precise temperature compensation.
- Two mA-outputs and
four SPDT relay contacts with display indicators.
- HART Communications
- FM Class 1, Div.2
Group A, B, C and D. T6 for Ta -20 to 50 degrees C
- Process data trending
up to 2 weeks.
|
| |
|
Windows |
| |
|
 |
PC Viewers PC202/402 |
 |
 |
- PC402 Includes RS485 modem
- PC202 Indluces HART modem
- Plug directly Into PC serial port
- No separate power supply required
- Very low powre CMOS
- Communicate with max.16 Yokogawa transmitters
|
 |
PC Configurator
PC150 |
 |
 |
- PC150 use HART modem
- Plug directly Into PC serial port
- No separate power supply required
- Communicate wiht one Yokogawa EXAxt
transmitters per serial port
- Full configuration upload and dowland
support
|
| |
|
Dissolved
Oxygen Converters |
| |
 |
Sensor and fittings for Dissolved
Oxygen
DO30/FD30/PB30
|
 |
 |
DO30
- Fast response
time
- Good long term
stability
PB30
- Easy to install
- Easy
calibration
FD30
|
 |
Dissolved Oxygen
Sensor SM31 |
 |
 |
- Fast
response
- Low
maintenance
- Long
lifetime
- Minimal
flow sensitivity
- Short
polarisation time
- Steam
sterilizable
-
Polargraphic sensor compatible with Yokogawa
DO402 Dissolved
|
 |
Dissolved Oxygen
Analysis DO202G |
 |
 |
- Universal input
accepts Galvanic and Polarographic sensors and various
temeprature compensating elements (Pt1000, 22k NTC)
- Fieldbus model for
Fieldbus Foundation
- Wide measuring range
including ppb, ppm and % saturation
- Automatic
temperature compensation from 0°C up to 100°C
- Certification for
hazardous area (ATEX, FM, CSA)
|
 |
Converter for Dissolved Oxygen DO402G
|
 |
 |
- Versatile
sensor inputs
- On-line
sensor checking monitors integrity of membrane
- RS485
communications interface
- Event
logbook in software
- Four fully
configurable SPDT contact outputs
- Two fully
configurable mA outputs
- Easy to use
EXA control panel
|
| |
|
Oxygen Analyzers |
| |
|
 |
Zirconia Oxygen Analyzer Averaging
Converter AV550G |
 |
 |
- Full color
touch screen.
- Special
trend graph functions with customer graph
configuration.
- Multiple
display modes shows average data, single
detector or all detector gas concentrations.
- Handles
input of up to 8 osygen detectors.
- "Hot swap"
of channel cards so the analyzer remains on line
while maintenance is performed.
|
|
 |
Separate Type Zirconia/High Temperature
Humidity Analyzer, Detectors ZR22G
|
 |
 |
- The built-in heater
assembly of the probe can be replaced on site, reducing
maintenance costs.
- The probe uses a
long-life, high-reliability Zirconia sensors.
- The separate type
converter incorporates a LCD touch-panel for ease of
operation.
- The integrated type
integrates both probe and converter, to reduce wiring,
piping, and installation costs. This type of unit uses
an optical switch for ease of operation at the site.
|
|
 |
Integrated Type Zirconia/High Temperature
Humidity Analyzer, Detectors ZR202G
|
 |
 |
- The built-in
heater assembly of the probe can be replaced on site,
reducing maintenance costs.
- The probe uses a
long-life, high-reliability Zirconia sensors.
- The separate type
converter incorporates a LCD touch-panel for ease of
operation.
- The integrated
type integrates both probe and converter, to reduce
wiring, piping, and installation costs. This type of
unit uses an optical switch for ease of operation at
the site.
|
|
|
Separate Type Zirconia/High Temperature
Humidity Analyzer, Detectors ZR22G |
 |
 |
- The built-in
heater assembly of the probe can be replaced on site,
reducing maintenance costs.
- The probe uses a
long-life, high-reliability Zirconia sensors.
- The separate type
converter incorporates a LCD touch-panel for ease of
operation.
- The integrated
type integrates both probe and converter, to reduce
wiring, piping, and installation costs. This type of
unit uses an optical switch for ease of operation at
the site.
|
| |
|
pH / ORP
Meters |
| |
 |
4-wire
transmitter pH 450G |
 |
 |
-
Easy touchscreen operation
- IP66/NEMA4X 1/2DIN
enclosure for field mounting and panel mounting.
-
Unique HMI menu structure in 5 languages.
-
On-screen logbooks store calibration data, configuration
changes and events
-
Three sets of preloaded pH buffer standards.
|
 |
2-wire Transmitter for pH and Redox
PH202G/S |
 |
 |
- Universal pH/ORP,
dual high impedance inputs
- On-line sensor
checking
- HART
communications interface
- Differential
input amplifier with equipotentiol screening
- Freely
configurable ITP, slope and assymmetry
- Password
protection for all levels of software
|
 |
2-wire
Transmitter for pH and Redox pH202G-F
|
 |
 |
- Universal pH/ORP,
dual high impedance inputs
- On-line sensor
checking
- HART
communications interface
- Differential
input amplifier with equipotentiol screening
- Freely
configurable ITP, slope and assymmetry
- Password
protection for all levels of software
|
 |
Panel Mount pH Measurement
System PH100 |
 |
 |
- 96 x 96 mm panel
mount design for indoor use
- Easy access to
routine maintenance mode
- Practical functions
packed in a compace housing
- One analog output
and two/four contact outputs as standard
- Simple one touch
automatic calibration
- Large 4-digit
display
|
 |
Sensor simulator
QT40G |
 |
 |
- Sensor simulator
for quick and accurate checking of equipment for
conductivity measurement.
- High accuracy of
resistance value adjustments by scale readings.
- Plug/socket
connector for direct connection to sensor cable
- Suitable for use
"in the field".
- Leahter carrying
case complete with test cable for direct connection to
conductivity equipment.
|
 |
pH/ORP Meter |
 |
 |
- 96 x 96 mm panel mount design for indoor use
- Practical functions packed in a compact housing
- Large 4-degit digital indication
- One analog output and two/four contact outputs as
standard
- Simple one touch automatic calibration
- Self-diagnostics (e.g., calibration failure,
measuring range failure, converter failure)
|
 |
Industrials
electrodes for pH SM21/SR20/SC21 |
 |
 |
- Wide range of
electrodes to suit all process conditions.
- Gold plated spring
O connector parts, for good electrical contact under the
most severe conditions.
- Coaxial plug and
socket with watertihgt sealing that meets the
requirements of OP65.
- Colou coded strips
for easy identification of electrodes and cables.
- High degree of
standardisation for mounting in flow-and immersion
fittings.
|
 |
Industriales
electrodes for pH SC21 Heavy
duty |
 |
 |
- Wide range of
electrodes to suit all process conditions.
- Gold plated
spring O connector parts, for good electrical contact
under the most severe conditions.
- Coaxial plug and
socket with watertihgt sealing that meets the
requirements of OP65.
- Colou coded
strips for easy identification of electrodes and
cables.
- High degree of
standardisation for mounting in flow-and immersion
fittings.
|
|
 |
pH/Redox and temperature sensors FU20/25
|
 |
 |
- Simple maintenance
by comprehensive de design
- Extended life time
by polymerized electrolyte and porous PTFE diaphragm
- Rugged construction
by full Ryton material disign
- Complete with 5 or
10 meter fixed cable
- Twist lock version
available
- Direct in-line,
immersion or off-line installation
|
 |
Differential pH
sensor PH18 |
 |
 |
- Sterilizable pH
sensor
- All enamel
construction
- No reference
electrode or junction
- Easy installation
and commissioning
- No routine
maintenance
- Flexible
installation options
|
 |
Combined electrodes for biotech and
pharmaceutical
SC22 |
 |
 |
- Long-term stability
of calibration values
- Special membrane
and high stability internal buffer
- Easy installation
- Low maintenance
- Coated reference
junction technlogy
|
 |
pH/ORP Combination
Sensor PH20 "Tempress" |
 |
 |
- Patented
Temperature and Pressure compensation for long lige and
accuracy
- pH & ORP
simultaneous measurement with the EXA range of
transmitters
- Simple adapter
mounting design for easy and cost effective installation
- Integral Pt1000
temperature sensor for enhanced accuracy
- Fittins and
chemical cleaning
- Large volume of
gelled electrolyte for long life
|
 |
Flow fittings
FF/FS20 |
 |
 |
- Wide choice of
construction materials.
- High degree of
standardisation reduces spare holding requirenets.
- Direct mounting of
sensors with SIN dimensions.
- Liquid earth pin
for stable measurements.
- Chemical cleaning
system as an option for 2-, 3-, and 4-hole fitting.
- Brush cleaning
system as an option for 4-hole fitting only.
|
 |
Immersion
fittings for pH/ORP measuring loops
FD20 |
 |
 |
- Designed for
either pH or ORP measurements in tanks open vessels
and drains.
- Pre-selected
immersion length.
- Wide choice of
construction materials.
- Flange mounting.
- High degree of
standardisation reduces spare holding requirements.
- Liquid earth pin
for stable measurements.
|
 |
Retractable fitting for combined
pH/Reference Electrode PR20 |
 |
 |
- Designed to make
safe retraction under process pressure possible by
blocking the ball-valve handle.
- Adjustable
insertion depth for optimal positioning in the process.
- Integrated
temperature sensor (Pt100 or Pt1000)and liquid
earthing.
- Damped probe
retraction by o-ring friction with pressurized systems.
- Adaptable to most
installations by a range of options.
- Compatible with
Yokogawa sensor check.
|
 |
Compact pH Probes |
 |
 |
- Available for
flow-, insetion- and immersion mounting.
- Integrated liquid
earth for sensor diagnostics with the EXA PH-series.
- Electrode removal
withou twisting the cable.
- One combination
cable incorporating all leads and shields.
- All-in-one system
eases stock and order processing.
- Flow electrode
for severe fouling and poisoning applications.
|
 |
Cleaning System
FC20 |
 |
 |
- Designed for
in-line electrode cleaning in flow-and immersion
fittings of Yokogawa.
- Restricts
sediment formation on the electrodes and increases the
period between cleaning.
- Optimum cleaning
effect.
- Standardised
dimensions for mounting in an electrode hole of a
fitting.
|
 |
Junction
box and Connecting cable BA10/BP10/WF10 |
 |
 |
- Between measuring
plant and control room, especially when the distance
between these places is greater than the length of the
standard appropriate electrode cables, the connecting
aquipment can be an expedient method for connectig
sensor cables to a measuring instrument.
|
 |
Sensors Cables WU20 |
 |
 |
- Internal anti-niose
sheath for accurate measurement.
- Gold plated
spring O-connectors parts, for good electrical contact
under the most severe conditions.
- Coaxial plug and
socket with watertight sealing that meets the
requirements of OP 65.
- Cables for
industrial applications and for laboratory use are
available.
|
 |
Accessories and
Mounting Kit for pH/References Electrodes |
 |
 |
- For mounting
sensors (the types with non-DIN dimensions) in a
fitting and for competing measuring loops, Yokogawa
added a range of accessoris to the program of fittings
which can be indespensable tools for optimal measuring
results.
|
 |
Industrial
Electrodes for Redox measurements SM29/SC29 |
 |
 |
- Wide range of
electodes to suit many process conditins.
- gold plated
spring O connector parts, for good electrical contact
under the most severe conditions.
- Coaxial plug and
socket with wateright sealing that meets the
requirements of IP65.
- Colour coded
strips for easy identification of electrodes and
cables.
- High degree of
standardisation for mounting in flow- and immersion
fittings.
|
 |
pH/ORP Meter PH72 |
 |
 |
- Waterproof
(IP67), sealed case and connector cover to keep out
moisture
- Automatic and
Manual Calibration
- Large, easy-to-read
LCD display
- Auto or Manual
Temperature Compensation
- ORP Measurement
with appropriate electrode
- Auto power off
extends battery life
|
|
|