Coriolis Mass Flowmeter |
|
|
|

|
Rotamass 3-Series |
 |
|
 |
-
Mass flow meter for nearly all
fluids, including high viscosity liquids, slurries and
multiphase media.
-
A special detector decoupling
system isolates the detector from external loads or
vibrations.
-
High accuracy and high stability
over a wide range, not just under lab conditions.
-
Two analog outputs, 2 pulse
outputs or status-out and one status-in as standard
I/O.
-
HART communication function.
-
Wide temperature range -200°C to
350°C/-328°F to 662°F.
|
|
|
|
|
Magnetic Flowmetrs |
|
|

|
Magnetic Flowmeter ADMAG
SE - Integral Type |
 |
|
 |
- High Reliability -
Based on Field Proven Tchnology
- Compliance to World
Market Requirements - General Safety
- High Accuracy (0.5% of
flow rate)
- Easy Operation and
Maintenance - Parameter Setting with Touch Control
- Easily Visible Display
- The Large Visible LCD Panel
- Communication
Capability - HART or BRAIN as standard
|
|
|
|
|
|

|
Magnetic Flowmeter ADMAG SE - Remote
Flowtube |
 |
|
 |
- Kabel
převodník - detektor až do 300m
- High Reliability - Proven
Construction
-
Compliance to World Market Requirements - Explosion
Proof
- High
Accuracy (0.5% of flow rate)
- Easy Operation and
Maintenance - Light Weight and Easy Installation
-
Cost-effective
|
|
|
|
|
|

|
Magnetic Flowmeter ADMAG AXF -
Integral Flowmeter/Remote Flowtube |
 |
|
 |
- Flexible Electrical
Connectin Direction
- Fluid Adhesion Level
Diagnosis
- Enhanced Dual
frequency Excitation Method
- Improved Minimum
Conductivity
- Versatile Input/output
Function Now Available for Integral Flowmeter
|
|
|
|
|
|

|
Magnetic Flowmeter
Remote Converter ADMAG AXFA11 |
 |
|
 |
- Fluid Adhesion Level
Diagnosis
- "Easy Setup"
Parameters
- Two Types of
Accuracy - standard accuracy is 0.35% of Rate, and
High grade accuracy tape (0.2% of Rate) is also
available.
- Enhanced Dual
frequency Excitation Method
- Versatile Input/output
Function Now Available
|
|
|
|
|
|

|
Magnetic Flowmeter Remote Converter ADMAG AXFA14 |
 |
|
 |
- Fluid Adhesion Level
Diagnosis
- "Easy Setup"
Parameters
- Two Types of
Accuracy - standard accuracy is 0.35% of Rate, and
High grade accuracy tape (0.2% of Rate) is also
available.
- Enhanced Dual
frequency Excitation Method
- Versatile Input/output
Function Now Available
|
|
|
|
|
|

|
Vortex Flowmeter Digital Yewflo |
 |
|
 |
- Vortex Flowmeter for Liquids,
Steam and Gases
-
Temperature range -200°C up to +450 °C
-
New converter concept provides
diagnostic data based on the unique SSP Technology
-
Integral flow measurement for
precise results even under difficult installation
conditions
- Dual piezo
system ensuring high vibration immunity and shock
resistance
- Pressure
rates up to ANSI 1500/PN250
|
|
|
|
|
|
 |
Ultrasonic
Flowmeters, Portable Type US300PM |
 |
|
 |
- Two channel inputs as
standard
- Two current
outpust maximum (The flow data and the sound speed in
the liquid can be assigned at the same time)
-
RS232 serial interface as
standard
- Wall thickness
measurement function as standard (probes are optional)
-
Interactive setup menu for easy
installation
|
|
|
|
|
|

|
Ultrasonic
Flowmeter US300FM |
 |
|

|
- Maximum two channel
inputs (two paht measurement)possible
-
Two current outputs maximum
(The flow data and the sound speed in the liquid
can be assigned at the same time)
-
Small and light (depth
about 7 cm, weight about 2,8 kg)
-
Three types of transducers
cover the pipe size from 25mm to 6 500mm. For
the fluid temperature, one for general
temperature (up to 130 deg C) and the other for
high temperature (up to 200 deg C) is available.
-
Owing to its unique digital
signal processing the anti air bubble
performance is high.
|
|
|
|
|
|

|
Metal Short-stroke Rotameter
RAMC |
 |
|

|
- Different process connections
like flanges according to DIN and ANSI
-
All wetted parts in stainless
steel
- Accuracy class 1,6 resp. 2,5
with PTFE-lining according to VDI/VDE 3513
-
Indicator housing in stainless
steel, aluminium or plastic of protection class IP65
(IP67 on demand)
-
Maximum flow 0,025 - 130m³/h water
resp. 0,75 - 1400 m³/h air.
-
Local indication
without additional power supply
|
|
|
|
|
|

|
Short-tube
Rotameter
RAKC |
 |
|
 |
- Standard design with internal
thread
- Other process
connections on request
-
Without valve (vertical connection)
-
With valve (horizontal connection)
-
Pressure resistant (40, 100, 160
bar). Other ratings on request.
-
Optional output signal of 4-20 mA
by electronic transmitter.
|
|
|
|
|
|

|
Small Metal Rotameter
RAKD |
 |
|

|
- Different process connections
like internal threads and flanges.
- Version with controller
-
Accuracy class 4 )according VDI/VDE
3513)
- Maximum flow
range 1-250l/h water reso. 45-8000l/h air, portioned
in 13 flow ranges with a relation of 1:10
-
Inductive sensors as limit
switches also in Fail-Safe-version can be fit
-
Connection of common transformer
isolated barriers and transmitter power supplies
possible
|
|
|
|
|
|

|
Rotameter
RAGG |
 |
|
 |
- Large selection of measuring
ranges
- Anti-static
metering tubes for measurement of lower gas flow
-
High accuracy by free rotating
float even at low flow rates
-
Visual check of the medium
-
High corrosion resistance
-
Exact scale calculation at
changed process medium according to VDE/VDI fuidelines
3513 with the use of the flow table (option/PT)
|
|
|
|
|
|

|
Rotameter
RAGH |
 |
|
 |
- Wide measuring range
selection
- Anti-static
metering tubes for measurement
- Low pressure loss
-
Visible monitoring of the
measured medium
- Local
indication without resource
-
Selectable scale
-
Scale conversion for various
processes with the use of the flow table (option/PT
|
|
|
|
|
|

|
Rotameter
RAGL |
 |
|
 |
- Large selectin of measuring
ranges
- Anti-static
metering tubes for measurement of small quantities of
gas
- High accuracy of
free rotating float even at low flow rates
-
Non-powered local indication
-
Large selection of scales
-
Optional built-in valve
|
|
|
|
|
|

|
Rotameter
RAGK |
 |
|
 |
- Large selectin of measuring
ranges
- High accuracy of
free rotating float even at low flow rates
-
Visual check of the medium
-
Ecaxt scale calcutation at
changed process conditions according to VDE/VDI
guidelines 3513 wiht the use of the flow table (option/PT)
-
Non-powered local indication
|
|
|
|
|
|

|
Plastic Rotameter
RAQN |
 |
|

|
- Tradiční
kvalita od původce plováčkových průtokoměrů
- Breakage proof
-
Easy to handle
-
Highly corrosion-resistant
-
Low pressure loss
-
Visible monitoring of the
measured medium
- Local
indication without resource
-
Selectable scale
|
|
|
|
|
|
|
|

|
Batch
Controller
RFC414, Gas
and Steam Computer RFC415 and Flow Computer RFC405 |
 |
|

|
Batch Controller
- Displays batch total, preset
quantity, flow rate, and accumulated total
-
Dual relay outputs
-
Remote start/stop
Gas and Steam Computer
- Displays mass flow, corrected
volume and energy flow
- Temperature and pressure
compensation
- Dual range dp transmitter
inputs
Flow Comuputer
- Displays mass flow or
corrected volume for liquids
- Displays Total
- Temperature compensation
- Data loggin output
|
|
|
|
|