Absolute
Pressure |
|
|
 |
Absolute
Pressure Transmitter
EJA310A |
 |
|
|
-
Excellent performance and
stability
-
Compact and light-weight
design
-
Fieldbus communication
capability
-
Accuracy of Calibrated
Span - 0,075% of
Spanwhen/HAC is specified
-
Capsule: L -
0,67 to 10 kPa ,
M - 1,3 to 130 kPa,H - 0,03 to 3 MPa
- The EJA
Series is available with BRAIN, HART or FOUNDATION
fieldbus™ communication protocols
|
 |
Absolute and Gauge Pressure Transmitter EJA510A |
 |
|

|
- Accuracy of Calibrated Span 0,15%
- Span - capsule A: 10 to 200 kPa
-
- capsule B: 0,1 to
2 kPa
- -
capsule C: 0,5 to
10 MPa
- - capsule D: 5 to
50 MPa
- Output 4 - 20 mA DC
- Degrees of protection
IP67, NEMA4x
- Explosion Protected types- ExN, EExd
and EExia
|
 |
Absolute and
Gauge Pressure Transmitter
EJX510A |
 |
|
 |
- Accuracy of Calibrated Span 0,15%
- Span - capsule A: 8 až 200 kPa
- -
capsule B: 0,04 až
2 MPa
- -
capsule C: 0,2 až
10 MPa
- -
capsule D: 1 až
50 MPa
- Communications BRAIN or HART
- Explosion Protected
types - ExN, EExd
a EExia
|
|
|
|
Differential Pressure |
|
|
 |
Differential
Pressure Transmtter EJA110A (DPharp) |
 |
|
|
- Accuracy of Calibrated Span 0,04%
- Vibration Effects - less than 0,1% of URL
- Overpressure efects 16 MPa
- Span - capsule M: 1 to
100 kPa
- -capsule H:
5 to
500 kPa
- External zero adjustment
- Excellent performance
and stability
- Compact and light-weight design
|
 |
Differential
Pressure Transmitter EJX110A |
 |
|
|
- Accuracy of Calibrated Span 0,04%
- Vibration Effects - less
than 0,1% of URL
- Maximum
Pressure Limit 16 MPa
- Span - capsule M: 0,5 to 100 kPa
-
- capsule H: 2,5 to
500 kPa
- External Zero Adjustment
-
Explosion Protected types - ExN, EExd
a EExia
|
 |
Diferenční
tlak EJA120A |
 |
|
|
- High Performance
Draft Range
- Ambient Temperature
Effects - Total Effects per 28°C (50°F) Change
- Output - 4 - 20 mA
DC
- External Zero
Adjustment
- Damping Time
Constant (1st order)
- Mounting Position
Effects
|
 |
Differential
Pressure Transmitter EJA130A |
 |
|
|
- Accuracy of Calibrated Span 0,075%
- Maximum Pressure Limit 32 MPa
- Span - capsule M: 1 to 100 kPa
- -
capsule H: 5 to
500 kPa
- External Zero Adjustment
- Wetted Parts Materials
-
Static Pressure Effects - Total Effects per Change,
Effect on Zero
|
| |
|
Flow |
| |
 |
Low Flow
Transmtter
EJA115 (DOharp) |
 |
|
 |
- Span - L: Water 0,016 to 7,2 l/min. Air 0,44 to 198 Nl/min.
-
- M: Water 0,022 až 23 l/min. Air 0,63 až 635 Nl/min.
-
- H: Water 0,070 až 33 l/min. Air 2 až 910 Nl/min.
- Accuracy: ±5 of span
-
Degrees of Protection: IP67, NEMA4X
- Process
Temperature Limits -40 to +120 °C
- Power Supply Effects: ±0,005%/V
|
|
|
|
Level |
| |
 |
Flange Mounted Differential
Pressure Transmitter EJA210A (DOharp) |
 |
|
 |
- Accuracy of Calibrated Span 0,075%
- Span - capsule M: 1 to 100 kPa
- -
capsule H: 5 to
500 kPa
- Ambient Temperature Effects - Total Effects per
28°C (50°F) Change
- Diaphragm - Hastelloy C-276
- Explosion Protected types - ExN, EExd
a EExia
|
 |
Flange
Mounted Differential Pressure Transmitter
EJX210A |
 |
|
 |
- Accuracy of Calibrated Span 0,075%
- Span - capsule
M: 1 to 100 kPa
- -
capsule H: 5 to
500 kPa
- Outoput 4 - 20 mA DC,
corresponding to the measured differential pressure
-
Communication BRAIN or HART
-
Explosion Protected types - ExN, EExd
a EExia
|
 |
Flange
Mounted Differential Pressure Transmitter
EJA220A |
 |
|
 |
- Accuracy of Calibrated Span 0,075%
- Span - capsule M: 1 to 100 kPa
- -
capsule H: 5 to
500 kPa
- External Zero Adjustment
- Diaphragm Hastelloy C-276
- Ambient Temperature Effects - Total Effects per
28°C (50°F) Change
|
| |
|
Gauge Pressure Transmitter |
| |
 |
Gauge
Pressure Transmitter
EJA430A (DPharp) |
 |
|
 |
- Accuracy of Calibrated Span 0,075%
- Span - capsule A: 0,03 to 3 MPa
- -
capsule B: 0,14 to
14 MPa
- External Zero Adjustment
- Process
Temperature Limits, -40 to 120 °C(-40-248°F)
-
Excellent performance
and stability
-
Compact and light-weight
design
|
| |
 |
Gauge
Pressure Transmitter
EJX430A |
 |
|
 |
- Accuracy of Calibrated Span 0,04%
- Span - capsule A: 0,0175 to 3,5 MPa
-
- capsule B: 0,08 to
16 MPa
- Outputs: 4 - 20 mA DC
-
Degrees of Protection: IP67, NEMA4X, JIS CO920
-
Communication: HART or BRAIN
|
| |
 |
Gauge
Pressure Transmitter EJA440A (DPharp) |
 |
|
 |
- Accuracy of Calibrated Span 0,12%
- Span - capsule C: 5 to 32 MPa
- -capsule
D: 5 to
50 MPa
- Abmitent Temperature Effects per 28°C (50 °F)
-
Damping Time Constant (1st order)
- Diaphragm: Hasteloy
C-276
- Explosion Protected Type - ExN, EExd
and EExia
|
 |
Gauge
Pressure Transmitter (High Accuracy
Type) EJA 530A |
 |
|
 |
- Accuracy of Calibrated Span 0,15%
- Span - capsule A: 10 to 200 MPa
- -
capsule B: 1 to
2 MPa
- -
capsule C: 0,5 to
10 MPa
- -
capsule D: 5 to
50 MPa
- Ambient Temperature Effects - Total Effects per
28°C (50°F) Change
- Damping Time Constant (1st order)
|
 |
Absolute and
Gauge Pressure Transmitter
EJX 530A |
 |
|
 |
- Accuracy of Calibrated Span 0,1%
- Span - capsule A: 8 to 200 kPa
-
- capsule B: 0,04 to
2 MPa
-
- capsule C: 0,2 to
10 MPa
- -
capsule D: 1 to
50 MPa
- Response Time (All Capsules) - 95 msec
- Ambient
Temperature Effects per 28°C (50°F)
-
The EJX series is available with
BRAIN, HART, and FOUNDATION
fieldbus™ communication protocols
|
 |
Multivariable
Transmitter EJX910A |
 |
|
 |
Diferential Prassure
- Accuracy of Calibrated Span 0,1%
- Span - capsule L: 0,1 až 10 kPa
-
- capsule M: 0,5 až 100 kPa
- -
capsule H: 2,5 až
50 kPa
Static Pressure
- Span - capsule L:1 až 16 MPa abs
- -
capsule M,H: 1 až 25 MPa abs
Gauge Pressure
- Span - capsule L: 1 až 16 MP
- -
capsule M,H: 1 až 25 MPa
|
|
|
|
Capillaries |
| |
 |
Diaphragm
Sealed Differential Pressure Tranmsitters EJA118 W/N/Y (DPharp) |
 |
 |
-
Transmitter using capillaries filled
with fill fluid.
-
Span - capsule M: 2,5 to 100 kPa
- -capsule
H: 25 to 500 kPa
- Degrees of Protection: IP67, NEMA4X, JIS C0920
immersion proof
- External Zero Adjustment "◊" -
Continuously adjustable Resolution;0,01% of span
- Explosion Protected Type - ExN, EExd
and EExia
|
| |
 |
Diaphragm
Sealed Gauge Pressure Transmitter EJX118A |
 |
|
|
-
Transmitter using capillaries filled
with fill fluid.
- Span - capsule M: 2
to 100 kPa
-
- capsule H: 10 to 500 kPa
- Outputs: 4 - 20 mA
DC
- Ambient Temperature
Effects per 28°C (50°F)
- Communication: HART
or BRAIN,
and FOUNDATION fieldbus™
communication protocols.
|
| |
 |
Diaphragm
Sealed Gauge Pressure Transmitter
EJA 438W/N (DPharp) |
 |
 |
-
Transmitter using capillaries filled
with fill fluid.
- Span - capsule A: 0,06 to 3 MPa
- -
capsule B: 0,46 to 14 MPa
- Ambient Humidity Limits: 5 to 100% R.H.(at 40°C)
-
External Zero Adjustment "◊" - Continuously adjustable
Resolution;0,01% of span
- Power Supply Effect "◊": ±0.005%/V
(21.6 to 32 V DC, 350 Ω)
- Explosion Protected Type - ExN, EExd
and EExia
|
 |
Diaphragm
Sealed Gauge Pressure Transmitter
EJX438A |
 |
 |
-
Transmitter using capillaries filled
with fill fluid.
- Span - capsule A:
0,035 to 3,5 MPa
- -
capsule B: ZT 0,16 to 16 MPa
-
PT 0,16 to 7 MPa
-
Ambient Temperature
Effects per 28°C (50°F)
- Power Supply Effects (Output signal code D and E)
-
±0.005% per Volt (from 21.6 to 32 V
DC, 350 Ω)
-
Explosion Protected Type - ExN, EExd a EExia
|
| |